185 CFA-3000 Analyzer

185 CFA-3000 Analyzer

Hydrazine analyzer model 185 (CFA3018) ensures simple, convenient and stable operation. Install color-coded tubes into the relevant tanks with regents, install colorless and transparent tubes into the relevant tanks and press the button. Analyzer will automatically start calibration and then can be commissioned. After commissioning, the analyzer will perform calibration twice per week. Routine maintenance is simple. Reagents and reference solution shall be replaced once per three month. To ensure stable operation and low operating expenses of 185 model it is necessary to replace valve pump each year. Complete maintenance takes 1 hour per year.

Using additional integrated flow selector 185 model can take measurements of 6 consequent sample flows. Single analog output is used at normal conditions. Flow marker indicates the starting point of each new flow. Multiple output option is also available where a separate analog output is assigned to each sample flow. Multiple output option saves the last value of each output before update. Hydrazine analyzer model 185 has a pressurized reagent delivery system. Utility air is not obligatory for pumping system. 185 model uses a package measurement method. Updating occurs each 12 minutes. The device has the following security certificates: EN 61010-1, EN 55011, EN 50082-1:92

Hydrazine analyzer model 185 (CFA3018) ensures simple, convenient and stable operation. Install color-coded tubes into the relevant tanks with regents, install colorless and transparent tubes into the relevant tanks and press the button. Analyzer will automatically start calibration and then can be commissioned. After commissioning, the analyzer will perform calibration twice per week. Routine maintenance is simple. Reagents and reference solution shall be replaced once per three month. To ensure stable operation and low operating expenses of 185 model it is necessary to replace valve pump each year. Complete maintenance takes 1 hour per year.

Using additional integrated flow selector 185 model can take measurements of 6 consequent sample flows. Single analog output is used at normal conditions. Flow marker indicates the starting point of each new flow. Multiple output option is also available where a separate analog output is assigned to each sample flow. Multiple output option saves the last value of each output before update. Hydrazine analyzer model 185 has a pressurized reagent delivery system. Utility air is not obligatory for pumping system. 185 model uses a package measurement method. Updating occurs each 12 minutes. The device has the following security certificates: EN 61010-1, EN 55011, EN 50082-1:92