CVU portable conductivity measurement system

CVU portable conductivity measurement system

Portable conductivity measurement module includes 1065 analyzer and at least one 404 sensor. Devices are fixed in a protective casing, connected and calibrated as per NIST standards. All necessary components are included into the delivery set. CVU-01 model includes 404-11-17 sensor made on stainless steel with 0.01 constant cell size connected to 1056-01-20-38-AN analyzer securely fixed in the protective casing and calibrated as per NIST standards. CVU-02 model includes two 404-11-17 sensors made of stainless steel with 0.01 constant cell size connected to 1056-01-20-38-AN analyzer securely fixed in the protective casing and calibrated as per NIST standards.

Technological information and specifications of 1056 analyzer

Casing material Polycarbonate. NEMA 4X/CSA 4
Dust and moisture protection IP65
Cable conduit openings  It is possible to use ½ inch fitting or PG13.5.
Display  Monochrome graphic LCD. Resolution: 128 x 96 pxl. Display backlight. Active display surface: 58 x 78 mm (2.3 x 3.0 inch).
Ambient temperature and humidity  From 0 to 55 C, relative humidity from 5 to 95 % (without condensation).
Storage temperature from -20 to 60 С
Power supply and output signals  Optional 01 115/230 VAC, 50/60 Hz  without relay, not available for -27, -37 options
02 24 VDC and 4 signaling relays
03 Switch-selectable AC 85-265VAC, 50/60 Hz, 4 signaling relays
AN 4-20 mA current output.
DP Profibus DP Digital Communication + 4-20мА
HT HART® Digital Communication + 4-20мА
Input One of two insulated sensor inputs.
Accuracy of current output ± 0.05 mA at 25 °C
Camp connection specifications  Power socket (3 outputs): 24-12 AWG wires. Connector blocks on signal board: 26-16 AWG wires. Power socket connectors (4 outputs): 24-16 AWG wires. Connector blocks on signal relay: 24-12 AWG wires.
Weight/shipping weight (rounded to 0.5 kg): 1.5 /2.0 kg
Dimension 155 x 155 x 131 mm

Technological information and specifications of 404 sensor

Cell constant 0.01/cm, 0.1/cm,
Temperature interval  Option-17:   0-100ºC
Pressure Max. Option-17:  791 kPa (7.9 bar)
Wetted materials Option-17: Titanium, 303 stainless steel, PEEK, EPDM

Portable conductivity measurement module includes 1065 analyzer and at least one 404 sensor. Devices are fixed in a protective casing, connected and calibrated as per NIST standards. All necessary components are included into the delivery set. CVU-01 model includes 404-11-17 sensor made on stainless steel with 0.01 constant cell size connected to 1056-01-20-38-AN analyzer securely fixed in the protective casing and calibrated as per NIST standards. CVU-02 model includes two 404-11-17 sensors made of stainless steel with 0.01 constant cell size connected to 1056-01-20-38-AN analyzer securely fixed in the protective casing and calibrated as per NIST standards.

Technological information and specifications of 1056 analyzer

Casing material Polycarbonate. NEMA 4X/CSA 4
Dust and moisture protection IP65
Cable conduit openings  It is possible to use ½ inch fitting or PG13.5.
Display  Monochrome graphic LCD. Resolution: 128 x 96 pxl. Display backlight. Active display surface: 58 x 78 mm (2.3 x 3.0 inch).
Ambient temperature and humidity  From 0 to 55 C, relative humidity from 5 to 95 % (without condensation).
Storage temperature from -20 to 60 С
Power supply and output signals  Optional 01 115/230 VAC, 50/60 Hz  without relay, not available for -27, -37 options
02 24 VDC and 4 signaling relays
03 Switch-selectable AC 85-265VAC, 50/60 Hz, 4 signaling relays
AN 4-20 mA current output.
DP Profibus DP Digital Communication + 4-20мА
HT HART® Digital Communication + 4-20мА
Input One of two insulated sensor inputs.
Accuracy of current output ± 0.05 mA at 25 °C
Camp connection specifications  Power socket (3 outputs): 24-12 AWG wires. Connector blocks on signal board: 26-16 AWG wires. Power socket connectors (4 outputs): 24-16 AWG wires. Connector blocks on signal relay: 24-12 AWG wires.
Weight/shipping weight (rounded to 0.5 kg): 1.5 /2.0 kg
Dimension 155 x 155 x 131 mm

Technological information and specifications of 404 sensor

Cell constant 0.01/cm, 0.1/cm,
Temperature interval  Option-17:   0-100ºC
Pressure Max. Option-17:  791 kPa (7.9 bar)
Wetted materials Option-17: Titanium, 303 stainless steel, PEEK, EPDM