RB sensor with high level of protection against toxic effect

RB sensor with high level of protection against toxic effect

Basic RB model has body made on Kynar material. Sensor is equipped with “multi-reference” electrolytic contact (reference electrode is 6-times more protected against toxic effect) that allows to use the sensor in aggressive media. The device has easy servicing procedures and does not require any specific storage conditions.
RB546 model sensor can be cut-in or immersed. Extractable installation is available for RB547 model. RB model has glass measure electrode and multi-reference cell protecting the electrode from damage and toxic effect. Automatic temperature compensation is available in a standard delivery package.

Technological information and specifications of devices

Wetted materials

Kynar, glass.

Measurement range

from 0 to 14 pH

Temperature Max.

130°C at 276 kPa (absolute)

Pressure Max.

1035 kPa (absolute) at 70°C

Maximum pressure during sensor removal/introduction

448 kPa at 70°C

276 kPa at 130°C

Process connection

RB546 – insertion/submersion

RB547 – extractable

Connecting cable

In-built (4.5 or 9 meters)

Compatible transmitters

All transmitters manufactured by Rosemount Analytical

Basic RB model has body made on Kynar material. Sensor is equipped with “multi-reference” electrolytic contact (reference electrode is 6-times more protected against toxic effect) that allows to use the sensor in aggressive media. The device has easy servicing procedures and does not require any specific storage conditions.
RB546 model sensor can be cut-in or immersed. Extractable installation is available for RB547 model. RB model has glass measure electrode and multi-reference cell protecting the electrode from damage and toxic effect. Automatic temperature compensation is available in a standard delivery package.

Technological information and specifications of devices

Wetted materials

Kynar, glass.

Measurement range

from 0 to 14 pH

Temperature Max.

130°C at 276 kPa (absolute)

Pressure Max.

1035 kPa (absolute) at 70°C

Maximum pressure during sensor removal/introduction

448 kPa at 70°C

276 kPa at 130°C

Process connection

RB546 – insertion/submersion

RB547 – extractable

Connecting cable

In-built (4.5 or 9 meters)

Compatible transmitters

All transmitters manufactured by Rosemount Analytical